Indiviual & Collective Screen
发布时间:2019-12-02
Application
These cables are designed to connect electrical instrument circuits and provide communication services in and around process plants (e.g. petrochemical industry etc.).
Executive Standards:
BS EN 60228
BS EN 50228-7 instrumentation cable
BS PAS 5308 Instrumentation Cable
Flame retardant to BS EN 60332-3-24 & IEC60332-3-24
Specifications
• Conductors: Stranded (Class 2) or flexible (Class 5) copper conductors to BS EN 60228
• Insulation: PVC, XLPE, PE, FEP, PTFE, Silicon
• Pair Identification: Pairs will be numbered, pair colors can be customized according to clients’ requirement.
• Individual Screen: tinned copper drain wire under and incontact with aluminium/PETP laminated tape, cooper wire braided screen, Copper/PETP laminated tape
• Screen Isolation Tape: numbered PETP tape applied
over each individually screened pair
• Binder Tape: PETP tape 50% overlap
• Collective Screen: tinned copper drain wire(s) under and in contact with aluminium/PETP laminated tape
• Outer Sheath: PVC, PO
• Flame retardant to BS EN 60332-3-24 & IEC60332-3-24
• Voltage Rating: 300/500 V, 450/750